PRODUCT INFORMATION
Instructions for using ion exchange resin
- front page
- product
- Water Treatment Technology
- Technology Development Department
- Instructions for using ion exchange resin
Product Information
- heat treatment
-
water treatment
- Arsenic remover
- Desulfurizer
- Deaerator
- Water softener (calcium and magnesium ion removal)
- Carbon filter (removes odor and residual chlorine)
- Sand filter (removal of suspended impurities)
- Iron remover (removal of iron and manganese ions)
- RO water purifier
- Pre-backwash filter
- UV ultraviolet sterilizer
- Ion exchange resin
- reverse osmosis membrane tube
- quick filter
- Various tanks for water treatment
- Various application filter media
- 美國 Clack Clark control valve
- 美國 Fleck Control Valve
- 美國 Pentair Control Valve
- 美國 Autotrol Control Valve
- Runxin Control Valve
- Injection treatment
- Technology Development Department
-
brand
- Demo brand
- US DOW
- IDEX USA
- US CLACK
- EMERSON, USA
- American PENTAIR
- SIEMENS Germany
- American PULSAFEEDER
- Denmark DANFOSS
- Thailand HAYCARB
- France SUNTEC
- UK PUROLITE
- Japanese NOP
- Japan OLYMPIA
- Japan KATSURA
- BRAHMA, Italy
- SAGINOMIYA
- HONEYWELL
- AZBIL (YAMATAKE)
- OLTREMARE
- NIPCON
- TROCHOID
- domestic
- EGO
- KATO
- LECIP
- ATS
- JACOBI
- ETATRON
- WAVE CYBER
- BOSCHINI
- NIPPON
- WL
- CASH ACME
- YAZAKI
- RUNXIN
- About | Contact
Instructions for using ion exchange resin
Technical explanation
How to use ion exchange resin:
1.) Regularly sample the resin to identify potential organic fouling (bacterial contamination) problems.
2.) Regularly replace the activated carbon pre-filtering equipment.
Frequently asked questions about ion exchange resin equipment design:
• DI equipment is often designed to be too large, and it needs to be checked and calculated according to the standard, and then the most suitable size is designed according to the data.
• The optimal flow rate of ion exchange resin is 6-10 Gal./Min./Ft2
• The optimal flow rate for polishing ion exchange resin is 20 Gal./Min./Ft2
• The frequency of resin regeneration is recommended at least once a week to control bacterial growth
• For the recirculation loop of the DI system, the recommended flow rate is 5 Gal./Min./Ft2. But it is recommended to use UV ultraviolet sterilization
• The minimum design regeneration expansion ratio of the twin bed DI system is 50%, and the best design regeneration expansion ratio of the mixed bed DI system is 100%