Jadesun Logo
02-2331-1097

Monday to Friday 8:30am~5:30pm

join us contact us

Product Inquiry List

After sending your product inquiry list, our relevant business unit will contact you as soon as possible

Send a product enquiry list

PRODUCT INFORMATION

Instructions for using ion exchange resin

Product Information

Instructions for using ion exchange resin

Technical explanation

How to use ion exchange resin:
1.) Regularly sample the resin to identify potential organic fouling (bacterial contamination) problems.
2.) Regularly replace the activated carbon pre-filtering equipment.

Frequently asked questions about ion exchange resin equipment design:
• DI equipment is often designed to be too large, and it needs to be checked and calculated according to the standard, and then the most suitable size is designed according to the data.
• The optimal flow rate of ion exchange resin is 6-10 Gal./Min./Ft2
• The optimal flow rate for polishing ion exchange resin is 20 Gal./Min./Ft2
• The frequency of resin regeneration is recommended at least once a week to control bacterial growth
• For the recirculation loop of the DI system, the recommended flow rate is 5 Gal./Min./Ft2. But it is recommended to use UV ultraviolet sterilization
• The minimum design regeneration expansion ratio of the twin bed DI system is 50%, and the best design regeneration expansion ratio of the mixed bed DI system is 100%