OM series diesel burning machine (3-30 L/Hr)

Product Information

OM series diesel burning machine (3-30 L/Hr)

日本 Olympia Original

日本 Olympia Co., Ltd. has nearly 70 years of burner development and research technology, with an annual production of more than 50,000 burners, and the market share of 日本 is more than 70%. Olympia burners are widely used in Taiwan: heat transfer oil stoves, incinerators, hot blast stoves, industrial and commercial furnaces, food drying, kitchen utensils, painting, steam, die casting, ovens, ironing and other thermal industries.

 

The gun type (GUN TYPE) automatic burner is composed of the body and automatic control parts. It is not necessary to reorganize the pump, gas ignition, automatic control and the trouble of wiring and piping during installation. , Small horsepower, low power consumption, no noise, strong capacity, large firepower, no need to use gas ignition, using automatic computer program to control the electric eye to monitor the flame, the use of card-type maintenance is very simple. The principle of spray gun type <GUN TYPE> is to use high pressure spray, atomization can reach 99.9% complete combustion, it is not necessary to use wind pressure to blast the spray, resulting in excess air volume to take away heat loss, and can improve fuel economy.

 

The OM series is the standard model among many diesel series models. The combustion capacity ranges from the smallest 3L/Hr to the largest 30L/Hr, etc., for many models to choose from. In addition to the most basic ON-OFF control, the operation control also includes the electromagnetic suction type damper control developed by ourselves, and the LOW-HIGH control that uses the air volume of the damper motor to switch between the air volume and the solenoid valve to change the gas consumption, etc. multiple choices. Besides heavy oil models, special diesel heaters for cold regions can also be installed separately. Applicable to: die casting machine, paint furnace, boiler, incinerator, fryer, dryer.

 

Features:
日本 original, the whole machine imported.
Stable performance and long service life.
Beautiful appearance, reasonable structure, lightweight design, complete functions but not occupying space.
Fully automatic control, easy operation and installation, easy maintenance.
Rotating flange design for easy installation and maintenance.
There are protection measures such as wind pressure, gas pressure switch and flame monitoring.
Applicable to all kinds of boilers, heating furnaces, hot blast stoves, forging furnaces, incinerators.

High-pressure atomization method can effectively achieve complete combustion and reduce fuel costs

High-voltage ignition method, and equipped with flame monitoring device, safe and reliable

 

 

日本 Olympia original product specifications

Fuel quantity (1/h) 2-5
way to control on-off
power supply Voltage V: 220/100 Phase: 1
Motor (W) 40
pump VS-C63

日本 Olympia Original Dimensions

TYPE
A
B
C
D
E
F
G
H
I
L
M
N
OM-0N
88
100
120
116
325
122
314
143
379
φ135
φ190
11
OM-1N
88
100
130
167
402
122
351
137
357
φ135
φ180
11
OM-2N
114
120
150
180
490
128
366
155
490
φ190
φ220
12
OM-3N
127
150
160

253

568
144
425
191
446
φ340
φ270
12
Fuel quantity (1/h) 2-5
way to control second stage fire
power supply Voltage V: 220/100 Phase: 1
Motor (W) 40
pump VS-CD63

日本 Olympia Original Dimensions

TYPE
A
B
C
D
E
F
G
H
I
L
M
N
OM-0N
88
100
120
116
325
122
314
143
379
φ135
φ190
11
OM-1N
88
100
130
167
402
122
351
137
357
φ135
φ180
11
OM-2N
114
120
150
180
490
128
366
155
490
φ190
φ220
12
OM-3N
127
150
160

253

568
144
425
191
446
φ340
φ270
12
Fuel quantity (1/h) 2-7
way to control on-off
power supply Voltage V: 220/100 Phase: 1
Motor (W) 150
pump VS-C90

日本 Olympia Original Dimensions

TYPE
A
B
C
D
E
F
G
H
I
L
M
N
OM-0N
88
100
120
116
325
122
314
143
379
φ135
φ190
11
OM-1N
88
100
130
167
402
122
351
137
357
φ135
φ180
11
OM-2N
114
120
150
180
490
128
366
155
490
φ190
φ220
12
OM-3N
127
150
160

253

568
144
425
191
446
φ340
φ270
12

 

Fuel quantity (1/h) 2-7
way to control second stage fire
power supply Voltage V: 220/100 Phase: 1
Motor (W) 150
pump VS-CD63

日本 Olympia Original Dimensions

TYPE
A
B
C
D
E
F
G
H
I
L
M
N
OM-0N
88
100
120
116
325
122
314
143
379
φ135
φ190
11
OM-1N
88
100
130
167
402
122
351
137
357
φ135
φ180
11
OM-2N
114
120
150
180
490
128
366
155
490
φ190
φ220
12
OM-3N
127
150
160

253

568
144
425
191
446
φ340
φ270
12
Fuel quantity (1/h) 2-7
way to control on-off
power supply Voltage V: 220/100 Phase: 1
Motor (W) 40
pump VS-C63

日本 Olympia Original Dimensions

TYPE
A
B
C
D
E
F
G
H
I
L
M
N
OM-0N
88
100
120
116
325
122
314
143
379
φ135
φ190
11
OM-1N
88
100
130
167
402
122
351
137
357
φ135
φ180
11
OM-2N
114
120
150
180
490
128
366
155
490
φ190
φ220
12
OM-3N
127
150
160

253

568
144
425
191
446
φ340
φ270
12
Fuel quantity (1/h) 2-7
way to control second stage fire
power supply Voltage V: 220/100 Phase: 1
Motor (W) 40
pump VS-CD63

日本 Olympia Original Dimensions

TYPE
A
B
C
D
E
F
G
H
I
L
M
N
OM-0N
88
100
120
116
325
122
314
143
379
φ135
φ190
11
OM-1N
88
100
130
167
402
122
351
137
357
φ135
φ180
11
OM-2N
114
120
150
180
490
128
366
155
490
φ190
φ220
12
OM-3N
127
150
160

253

568
144
425
191
446
φ340
φ270
12
Fuel quantity (1/h) 3-12
way to control on-off
power supply Voltage V: 220/100 Phase: 1
Motor (W) 150
pump GFS-VA

日本 Olympia Original Dimensions

TYPE
A
B
C
D
E
F
G
H
I
L
M
N
OM-0N
88
100
120
116
325
122
314
143
379
φ135
φ190
11
OM-1N
88
100
130
167
402
122
351
137
357
φ135
φ180
11
OM-2N
114
120
150
180
490
128
366
155
490
φ190
φ220
12
OM-3N
127
150
160

253

568
144
425
191
446
φ340
φ270
12